VLF-series
Portable High-voltage Test System

Kategoriler:

Açıklama

VLF-series is design for VLF testing of cables with XLPE insulations AC testing voltage up 34 kV (60 or 80 kV) peak with frequency 0.02, 0.05 or 0.1 Hz (0.01 Hz – option). This unit is a portable system in a single unit uses smart quick intelligent power testing system.

TECHNICAL SPECIFICATIONS:

Parameter VLF-34 VLF-60 VLF-80
Output voltage (peak) 34 kV 60 kV 80 kV
Type wave sine sine sine
Output frequency 0.1, 0.05, 0.02 Hz (0.01 Hz – option) 0.1, 0.05, 0.02 Hz (0.01 Hz – option) 0.1, 0.05, 0.02 Hz (0.01 Hz – option)
Output current 10 mA 10 mA 10 mA
Output voltage accuracy ± 3 % ± 3 % ± 3 %
Waveform distortion ± 5 % ± 5 % ± 5 %
Load carrying capacity 0.1 Hz ≤ 1.1 μF
0.05 Hz ≤ 2.2 μF
0.02 Hz ≤ 5.5 μF
0.01 Hz ≤ 7.0 μF
0.1 Hz ≤ 1.1 μF
0.05 Hz ≤ 2.2 μF
0.02 Hz ≤ 5.5 μF
0.01 Hz ≤ 7.0 μF
0.1 Hz ≤ 1.1 μF
0.05 Hz ≤ 2.2 μF
0.02 Hz ≤ 5.5 μF
0.01 Hz ≤ 7.0 μF
Power supply 220 V 220 V 220 V
Power frequency 50/60 Hz 50/60 Hz 50/60 Hz
Current consumption 20 A (peak),
15 A (average)
20 A (peak),
15 A (average)
20 A (peak),
15 A (average)
Power consumption 3 kW 3 kW 3 kW
Power fuse tube 8 A 10 A 20 A
Dimensions 400×280×660 mm 560×240×770 mm 560×240×770 mm
Weight 30 kg 55 kg 65 kg

 

 